Sign In | Join Free | My uabig.com
China Xi'an Kacise Optronics Co.,Ltd. logo
Xi'an Kacise Optronics Co.,Ltd.
Kacise, understanding your automation needs.
Verified Supplier

7 Years

Home > Water Quality Sensor >

Dual High Impedance KPH601 Online PH Sensor Differential Amplifier

Xi'an Kacise Optronics Co.,Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Dual High Impedance KPH601 Online PH Sensor Differential Amplifier

  • 1
  • 2

Brand Name : kacise

Model Number : KPH601

Certification : CE

Place of Origin : CHINA

MOQ : 0-100

Price : $0-$150

Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram

Supply Ability : 100

Delivery Time : 3-10days

Packaging Details : Common package or custom package

Measuring Range : 0~14pH

Resolution : 0.01pH

Accuracy : ±0.1pH

Working Temperature : 0~65℃

Working Pressure : <0.2MPa

Temperature Compensation : Auto temperature compensation (NTC)

Contact Now

KPH601 Online PH Sensor Signal Output: RS-485 (Modbus/RTU Protocol)

1.Why are pH values measured?

We measure pH for a lot of different reasons, such as:

to produce products with defined properties – During production it is important to control the pH to ensure that the end product conforms with the desired specifications. The pH can dramatically alter the properties of an end product such as appearance or taste.

to lower production costs – This is related to the above-mentioned reason. If the yield of a certain production process is higher at a given pH, it follows that the costs of production are lower at this pH.

to avoid doing harm to people, materials, and the environment – Some products can be harmful at a specific pH. We must be careful not to release these products into the environment where they can be a danger to people or damage equipment. To be able to determine whether such a substance is dangerous we first must measure its pH value.

to fulfill regulatory requirements – As seen above, some products can be harmful. Governments therefore put regulatory requirements in place to protect the population from any damage caused by dangerous materials.

to protect equipment – Production equipment that comes into contact with reactants during the production process can be corroded by the reactants if the pH value is not within certain limits. Corrosion shortens the lifetime of the production line, therefore monitoring pH values is important to protect the production line from unnecessary damage.

for research and development – The pH value is also an important parameter for research purposes such as the study of biochemical processes.

2.Industrial pH measurement

The pH electrode assembly should be mounted in a place where it is easily reached and where defined conditions exists. Unlike laboratory measurements, industrial measurements are mainly continuous (on-line). Usually the process occurs in closed stirring vessels (chemical reactors, bioreactors). Measurements may, however, also be taken in pipe-lines, basins, or open canals. The process conditions may be very different. In addition to high temperatures and pressures, an electrical current may also have to be considered. An industrial pH electrode assembly consisting of a pH electrode and an electrode housing must be adapted to these circumstances. For industrial processes efficiency is critical. Hence, simple maintenance is of main interest. The choice of a suitable pH electrode assembly is determined by the installation possibilities. Ideally, a pH electrode assembly should be mounted in a place that is easily reached and where representative and defined conditions of the process exist. In a stirred vessel the electrode assembly is often installed laterally with the aid of a weld-in socket. Flange joints or screw connections are also used. In order to ensure that the glass membrane is always filled with the inner buffer an installation angle of at least 15° above horizontal should be used. It is difficult to install side mounted lateral support fittings in vessels with an inner lining of glass, enamel or rubber. In these vessels pH measurements must therefore be made through the cover with very long electrode assemblies. Especially in vessels containing solid components the stirring forces have to be considered. A basic principle is to make sure that the pH electrode assembly remains immersed in the solution, independent of the level of the solution. If there are no more free ports available in the cover, the pH value may be measured in a bypass. In this measuring arrangement you have to take a delayed change of the pH value into account. The installation of the bypass system must be done in such a way that clogging does not occur.

3.Technical Specifications

Model KPH601
Measuring Range 0~14pH
Resolution 0.01pH
Accuracy ±0.1pH
Working Temperature 0~65℃
Working Pressure <0.2MPa
Temperature Compensation Auto temperature compensation (NTC)
Power Supply 12~24VDC ±10%
Signal Output RS-485(Modbus/RTU)
Wetted Material POM
Mounting Method Immersion mounting, 3/4 NPT thread
Cable Length 5 meters, other lengths can be customized
Calibration Two-point calibration
Power Consumption <0.3W@12V
Protection Grade IP68

4.Dimensional Drawing

Dual High Impedance KPH601 Online PH Sensor Differential Amplifier

Note:The sensor connector is M16-5 core waterproof joint male head.

5.Installation

Dual High Impedance KPH601 Online PH Sensor Differential Amplifier

Note: The sensor should not be installed upside down or horizontally when installed, at least at an angle of 15 degrees or more.

Contact Us

Website www.kacise.com

Phone +86-17719566736

Email sales@kacise.com

Location Tangyan South Road, High-tech Zone, Xi'an City, Shaanxi Province, China

Dual High Impedance KPH601 Online PH Sensor Differential Amplifier


Wholesale Dual High Impedance KPH601 Online PH Sensor Differential Amplifier from china suppliers

Dual High Impedance KPH601 Online PH Sensor Differential Amplifier Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Xi'an Kacise Optronics Co.,Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)